Closed-Loop Controls image

Closed-Loop Controls

Closed-loop heater control systems use a power controller, temperature controller and thermocouple to monitor and provide a constant output temperature, regardless of changes in airflow. The typical temperature controller provides a convenient display of the air temperature measured by a thermocouple appropriately placed in the heaters air stream.  All standard control panel products are recommended for indoor use.  Custom solutions are available.  Contact support for details. 

fas fa-video fas fa-play-circle {{v.title}} Watch Videos
fas fa-wrench Show Options
Get A Quote fas fa-pencil-ruler Closed-Loop Controls fas fa-pencil-ruler Tutco_SureHeat_Controller_6-19_1.pptx

F075526

Compatible with: Jet or Max 240V, Single Phase, Under 40A

Description:

  • Indoor use only
  • Input: 240V, 50/60Hz, 40A, Single Phase
  • RS-232 Serial Communication
  • UL Recognized, CE, RoHS

F078254

Coming Soon

Compatible with: Series, Hot Air Tools, Serpentine II, Threaded Inline and other 240V, Single Phase, Process Air Heaters Under 20A

Description:

  • Indoor use only
  • Input: 240V, 50/60Hz, 20A, Single Phase
  • 20"H x 16"W x 8"D  ( 508mm H x 407mm W x 204mm D ) 
  • 4" HMI Touchscreen with fully developed UX interface for TUTCO process air heater products 
  • Ethernet communications
  • High limit alarm
  • NEMA 12 enclosure
  • UL 508A, RoHS
  • Custom Options: Consult with tech support for custom features.
    • CE 
    • E-Stop / Power Disconnect
    • Multi-Zone - Connect up to 2 compatible heaters per control panel

F078255

Coming Soon

Compatible with: Series, Hot Air Tools, Serpentine II, Threaded Inline and other 240V, Single Phase, Process Air Heaters Under 40A

Description:

  • Indoor use only
  • Input: 240V, 50/60Hz, 40A, Single Phase
  • 20"H x 16"W x 8"D  ( 508mm H x 407mm W x 204mm D ) 
  • 4" HMI Touchscreen with fully developed UX interface for TUTCO process air heater products 
  • Ethernet communications
  • High limit alarm
  • NEMA 12 enclosure
  • UL 508A, RoHS
  • Custom Options: Consult with tech support for custom features.
    • CE 
    • E-Stop / Power Disconnect
    • Multi-Zone - Connect up to 2 compatible heaters per control panel

F078256

Coming Soon

Compatible with: Series, Hot Air Tools, Serpentine II, Threaded Inline and other 240V, Single Phase, Process Air Heaters Under 60A

Description:

  • Indoor use only
  • Input: 240V, 50/60Hz, 60A, Single Phase
  • 24"H x 16"W x 8"D  ( 610mm H x 407mm W x 204mm D ) 
  • 4" HMI Touchscreen with fully developed UX interface for TUTCO process air heater products 
  • Ethernet communications
  • High limit alarm
  • NEMA 12 enclosure
  • UL 508A, RoHS
  • Custom Options: Consult with tech support for custom features.
    • CE 
    • E-Stop / Power Disconnect
    • Multi-Zone - Connect up to 2 compatible heaters per control panel

​F078216

Compatible with: Max 380V, 3 Phase, Under 30A

Description:

  • Recommended for indoor use
  • Input: 380/400V, 50/60Hz, 30A, 3 Phase
  • 24"H x 24"W x 10"D ( 610mm x 610mm x 254mm) 
  • E-Stop installed in the front panel
  • Digital high-limit latching temperature controller
  • UL 508A, CE, RoHS

F078135

Compatible with: Threaded Inline, Max, Max HT 480V / 240V, Under 30A

Description:

  • Indoor use only
  • Input: 480V / 240V, 60Hz, 30A, 3 Phase
  • Ethernet Connection via Eurotherm Temperature Controller
  • 24"H x 24"W x 10"D ( 610mm x 610mm x 254mm ) 
  • UL 508A, RoHS

​F078136

Compatible with: Threaded Inline, Max, Max HT 480V / 240V, Under 60A

Description:

  • Indoor use only
  • Input: 480V / 240V, 60Hz, 60A, 3 Phase
  • Ethernet Connection via Eurotherm Temperature Controller
  • 24"H x 24"W x 10"D ( 610mm x 610mm x 254mm ) 
  • UL 508A, RoHS

F078217

Compatible with: Max, Max HT 380V, Under 60A

Description:

  • Indoor use only
  • Input: 380/400V, 50/60Hz, 60A, 3 Phase
  • 24"H x 24"W x 10"D ( 610mm x 610mm x 254mm ) 
  • E-Stop installed in the front panel
  • Digital high-limit latching temperature controller
  • UL 508A, CE, RoHS
    fas fa-home Home Process Air Heaters Closed-Loop ProcessThreaded InlineTriple Pass HeatersOpen-Loop Spot​Closed-Loop SpotSKORPION Air HeatersDetermine Your HeaterReplacement ElementsHeater Controls Custom Specialty Heaters Specialty Flanged InlineLow Pressure InlineThreaded InlineCustom Heating ElementsDevelopment ProcessCustomer List About Us HistoryTUTCO Heating Solutions GroupCareer OpportunitiesSales Terms & Conditions Vendor TermsWarrantyConflict MineralComplianceProp 65Privacy StatementAnti-Modern SlaveryRoHS DocumentCookies Statement Resources BlogIndustriesVideosTech DocumentsDistributorsInventory LookupCalculators Contact Us